EMEC ECL6 and ECL12 Chlorine Open Amperometric Cells

The ECL Range of EMEC Open Amperometric Cells offer simple operation for Chlorine measurement and control for dirty water applications. The EMEC ECL6 and ECL12 Open Amperometric Cells are used for fresh, and salt water Chlorine measurement respectively. To be used with the EMEC LDPHCL4-MA Controller, they offer ease of use, accuracy and reliability where readings are continuous, and updated every second. Built-in temperature and pH compensation are incorporated.

The example system below consists of the controller, filter, and flow cell Chlorine sensor:

Analyzer System on Backboard

EMEC Analyzer System on Backboard

Individual System Components

Model: EMEC LDPHCL4-MA

Dual Channel pH and Chlorine Controller for Open Amperometric Cells

EMEC Dual Channel pH and Chlorine Controller - Open Amperometric Cells
  • Dual Channel pH and Chlorine Control
  • Various Models of Chlorine Open Amperometric Cells available to suit
  • Programmable for dosing Acid/Base and Chlorine
  • Proportional or On/Off Control for pH and Chlorine
  • Outputs: 1 x pH 240Vac Relay, 2 x pH Pulse, 1 x Cl2 240Vac Relay, 1 x Cl2 Pulse
  • 3 x mA Outputs for pH, Chlorine & Temperature
  • Tanks level inputs: 2 x pH, 1 x Cl2
  • Inputs for Stand-by, and Flow
  • Alarm Relay Output and RS485 Port
  • LCD display shows measured pH and Chlorine (mg/L)
  • Manual/Automatic Temperature Compensation (for pH only)
  • Max dosing alarms
  • Compatible pH Probe required, and the EMEC Range of Open Chlorine Amperometric Sensors and Flow Cells
  • Optional GSM/GPRS modem or Ethernet/LAN card for remote connectivity via webserver and alarming via SMS/e-mail
  • Dirty Water Applications – Fresh or Salt Water
  • Cooling Towers
  • Swimming Pools
  • Nursery and Greenhouse
  • Agriculture
  • Waste Water Treatment

Model: EMEC ECL6

Open Amerometric Cell – Fresh Water

Model: EMEC ECL12

Open Amerometric Cell – Salt Water

EMEC ECL6 and ECL12 Chlorine Open Amerometric Cells
  • Organic & Inorganic, Free Chlorine Measurment for Hypochlorous Acid
  • Operating pH range of 6-8
  • Measuring range 0-10.00 ppm
  • 0.05 ppm Resolution
  • Temperature Range 5-40°C.  NOTE: 1% increase in CL2 reading per 1°C increase
  • 10 Bar Max Pressure
  • pH Temperature compensation of pH with optional EMEC ETEPT temperature sensor
  • pH Compensation of CL2 with optional EMEC EPHS pH sensor
  • Use EMEC ECL6 108.1646.1 with EMEC WDPHCL
  • Use EMEC ECL6 108.1365.1 with EMEC LDPHCL4
  • Chlorine and pH Control for Dirty Water Applications
  • Cooling Towers
  • Swimming Pools
  • Nursery and Greenhouse
  • Agriculture
  • Waste Water Treatment

Optional Re-circulation System for Calibration

Re-circulation System

Recirculated Generic Calibration Block Diagram