Chlorine / Chlorine Dioxide Analyzer and Control System

The EMEC Chlorine Analyzer Control System, offers ease of use, accuracy and reliability for the monitoring and control of Chlorine in water. Using the EMEC LDSCL PLUS analyzer and controller, and the latest in Amperometric Cell Technology, Chlorine ppm readings are continuous and updated every second. The same controller can be used for Chlorine Dioxide, incorporated with a different sensor. Built-in pH, and temperature compensation are standard.

The System below consists of the Controller, Filter, Flow Cell and Chlorine Sensor:

Analyzer System on Backboard

EMEC Analyzer System on Backboard

Individual System Components

Model: EMEC LDSCL PLUS

Chlorine or Chlorine Dioxide Controller

EMEC Chlorine / Chlorine Dioxide Analyzer & Controller
Now availalbe on e-store
  • PID Chlorine / Chlorine Dioxide Controller
  • User Friendly Encoder wheel menu, with back-lit LCD Display
  • Control Outputs for PID 4-20mA, 2 x Pulse, & 2 x Relay
  • 4-20mA Outputs for PPM, and Temperature
  • Alarm & Probe Cleaning relays
  • Communication via Ermes Webserver or modbus
  • Optional mA or pulse water meter inputs for Feed-forward control
  • Optional Communication interfaces for Ethernet, GSM, or Modbus
  • Optional Communication interface provides Ermes Web-server access for on-line monitoring and data-logging
  • Use with EMEC Series PEF Flow Cell, and SCL Amperometric Chlorine or Chlorine Dioxide Sensor
  • Disinfection Systems
  • Cooling Towers
  • Water Treatment

Model: EMEC PEF1R

Chlorine / Chlorine Dioxide Flow Cell & Probe Holder

EMEC Chlorine / Chlorine Dioxide Flow Cell
Now availalbe on e-store
  • Includes EMEC SEPR Flow sensor – Flow Indication via a Red LED
  • Built-in Temperature Sensor
  • Standard Tubing and Fittings
  • Includes Pressure & Flow Regulator
  • Flow Adjustment Knob
  • Built-in Sample Port
  • Use with EMEC SCL Series Amperometric Sensors

Model: EMEC SCL

Chlorine and Chlorine Dioxide Amperometric Sensors

EMEC Amperomectric Chlorine / Chlorine Dioxide Sensor
Now availalbe on e-store
  • EMEC SCL Digital sensors compatible with EMEC LDSCL PLUS Controllers
  • Digital interface to controller, for Auto sensor and Range detection
  • pH, and Temperature Compensated
  • 15 PSI (1 Bar) Max Pressure, or 115 PSI (8 Bar) for SCL17/18 Self-Cleaning Probes
  •  Chlorine Measurement Models:
    • SCL3S for free chlorine – Sodium Hypochlorite (organic and inorganic) for fresh water (0 – 20.00 ppm)
    • SCL3N for free chlorine – Sodium Hypochlorite (inorganic) for fresh water (0 – 2.000, 20.00 or 200.0 ppm)
    • SCL3N/0.5 for zero inorganic free chlorine – ideal for absence of Chlorine measurement for fresh water (0 – 0.500 ppm)
    • SCL18 self-cleaning for free chlorine – Sodium Hypochlorite (inorganic) for dirty water (0 – 2.000 or 20.00ppm)
    • SCL18/0.5 self-cleaning for zero inorganic free chlorine – ideal for absence of Chlorine measurement for dirty water (0 – 0.500 ppm)
    • SCL8 for total chlorine (0 – 2.000 or 20.00 ppm)
  • Chlorine Dioxide Measurement Models:
    • SCL2 for chlorine dioxide (0 – 0.500, 2.000 or 20.00 ppm)
    • SCL17 self-cleaning for chlorine dioxide, for dirty water (0 – 0.500, 2.000 or 20.00 ppm)

Optional Re-circulation System for Calibration

Re-circulation System

Recirculated Generic Calibration Block Diagram

Related Products