PR Electronics Signal Splitters

PR Electronics Signal Splitters provide 3-way galvanic isolation between input, output and power supply, completely isolating all external devices. They offer Extremely High Accuracy and Reliability for the Industrial market, and each unit is factory tested to 2.5KVA isolation potential.

Used in the Oil & Gas, Pharmaceutical, Water and Waste Water, Cement and Process Control Industries, these transmitters offer superior quality and high performance, with certain models offering the unique clip-on display programmer. A 5 year warranty is standard for all products.

For the complete range, and application assistance please contact us.

Products

Model: PR-3109

Slim Line Signal Splitter

PR Electronics Model PR-3109 Signal Splitter
  • Input: mA, Loop Power, or Volts
  • Outputs: 2 x Galvanically Isolated mA, and/or Volt Signals
  • Power Supply: 24Vdc or Power Rail
  • Dip Switch Configurable
  • 6mm Slim Line Housing
  • 2.5KV Galvanic 3-Way Isolation (Input, Output & Supply)
  • UL & FM Approved for Class 1, Div 2
  • Signal Splitting and Isolation
  • Process signals can be transmitted to the PLC, and a secondary Chart Recorder or Panel Meter Display
  • Eliminates Ground Loop Faults

Model: PR-3185A2

Loop Powered Slim Line Signal Splitter

PR Electronics Model PR-3185A2 Loop Powered Signal Splitter
  • Input: Loop Powered mA for Signal Splitter
  • Can also be used to Isolate 2 x Individual Loop Powered mA  signals
  • Outputs: 2 x Galvanically Isolated mA Signals
  • 6mm Slim Line Housing
  • 2.5KV Galvanic Isolation (Input to Output)
  • UL & FM Approved for Class 1, Div 2
  • Signal Splitting and Isolation
  • Process signals can be transmitted to the PLC, and a secondary Chart Recorder or Panel Meter Display
  • Eliminates Ground Loop Faults

Model: PR-9106A1B

mA Signal Splitter / HART Repeater

PR Electronics Model PR-9106A1B Signal Splitter
  • Input: Bridge the Dual mA Input Terminals to Achieve Splitter Function
  • Can also be used as a Dual Input mA HART Transparent Isolator/Repeater
  • HART Transparent Dual Active and Passive Inputs
  • Outputs: 2 x Galvanically Isolated mA Signals (Active or Passive)
  • Power Supply: 24Vdc or Power Rail
  • Optional PR-4501 or PR-4511 Front Face Display to View mA Inputs / Outputs
  • 2.6KV Galvanic 3-Way Isolation (Input, Output & Supply)
  • Device Status Relay
  • UL & FM Approved for Class 1, Div 2
  • Signal Splitting and Isolation
  • Process signals can be transmitted to the PLC, and a secondary Chart Recorder or Panel Meter Display
  • Eliminates Ground Loop Faults