Multi Parameter Water Analyzer / Controllers
For Ease of Use, Accuracy and Reliability, the EMEC and RealTech Controls range of Multi Parameter Water Analyzer / Controllers provide cost effective process monitoring and control. Dual and Multi-Variable Controllers are available for customized solutions.
For the complete range, and application assistance, please contact us.
The range of EMEC Multi Parameter Water Analyzer / Controllers are listed below:
- Model: EMEC LDPHRH-MA Dual Channel pH and ORP
- Model: EMEC LDPHPH-MA Dual Channel pH and pH
- Model: EMEC LDCDCD-MA Dual Channel Conductivity and Conductivity
- Model: EMEC LDPHCD-MA Dual Channel pH and Conductivity
- Model: EMEC LDPHTORB2-MA Dual Channel pH and Turbidity
- Model: EMEC LDPHCL1-MA Dual Channel pH and Chlorine
- Model: EMEC CENTURIO PRO Six Channel Controller
Multi Parameter Water Analyzer Related Products:
Products
- Dual mA Outputs for the measured variables
- 3 x Programmable relays for control or alarms
- MODBUS RTU output
- Simulation function for measured variables
- Backlit LCD displays shows both measured variables, with % mA output
- Auto-detects sensors for Chlorine, pH, ORP, Conductivity, Resistivity, and Dissolved Oxygen.
- Optional HART output
- Options for Loop Powered, or 24Vdc power supply
- Manual/Automatic Temperature Compensation (for pH and Chlorine)
- Water Sanitizer Control
- Water / Waste Water Treatment
- Greenhouse and Nursery
- Swimming Pools and Fountains
- Food and Beverage
- Dual Control of both pH and ORP
- BNC Connector Probe Connections
- Programmable for dosing acid and/or base, and Chlorine
- Proportional or On/Off Control for pH and ORP
- Outputs: 1 x pH 240Vac Relay, 2 x pH Pulse, 1 x ORP 240Vac Relay, 1 x ORP Pulse
- 3 x mA Outputs for pH, ORP & Temp
- Tanks level inputs: 2 x pH, 1 x ORP
- Inputs for Stand-by, and Flow
- 1 x 240Vac Alarm Relay O/P, 1 x RS485 O/P
- LCD displays show measured pH and ORP (mV)
- Manual/Automatic Temperature Compensation (for pH only)
- Max dosing alarms
- Optional GSM/GPRS modem or Ethernet/LAN card for remote connectivity via webserver and alarming via SMS/e-mail
- Water Sanitizer Control
- Alternative to Chlorine or Chlorine Dioxide ppm Measurement
- Greenhouse and Nursery
- Waste Water Treatment
- Programmable for control of 2 individual pH systems
- BNC Connectors for pH Probes
- Proportional or On/Off Control 2 x pH systems
- Control Outputs: 1 x pH1 240Vac Relay, 2 x pH1 Pulse, 1 x pH2 240Vac Relay, 1 x pH2 Pulse
- 3 x mA Outputs for pH1, pH2 & Temp
- Tanks Level inputs: 2 x pH1, 1 x pH2
- Other I/O: 1 x Standby I/P, 1 x 240Vac Alarm Relay O/P, 1 x RS485 O/P
- LCD displays shows both measured pH values
- Manual/Automatic Temperature Compensation
- Max dosing alarms
- Optional GSM/GPRS modem or Ethernet/LAN card for remote connectivity via webserver and alarming via SMS/e-mail
- Redundant pH Measurement and Control
- Critical Process Monitoring and Control
- Cost Effective – Dual Measurement on One Controller
- Dual Channel Conductivity Controller
- Suits EMEC Conductivity Probes
- Proportional or On/Off Control for 2 x Conductivity systems
- Control Outputs: 1 x CD1 240Vac Relay, 2 x CD1 Pulse, 1 x CD2 240Vac Relay, 1 x CD2 Pulse
- 3 x mA Outputs for CD1, CD2 & Temp
- Tanks Level inputs: 2 x CD1, 1 x CD2
- Other I/O: 1 x Standby I/P, 1 x 240Vac Alarm Relay O/P, 1 x RS485 O/P
- LCD displays shows both measured Conductivity values
- Manual/Automatic Temperature Compensation
- Max dosing alarms
- Optional GSM/GPRS modem or Ethernet/LAN card for remote connectivity via webserver and alarming via
- Dual Conductivity Measurement and Control
- Cooling Towers
- Agriculture
- Waste Water Treatment
- Water Tank Corrosion Control
- Dual Channel pH and Conductivity Controller
- Programmable for dosing acid and/or base, and Conductivity control
- Proportional or On/Off Control for pH and Conductivity
- Outputs: 1 x pH 240Vac Relay, 2 x pH Pulse, 1 x Conductivity 240Vac Relay, 1 x Conductivity Pulse
- 3 x mA Outputs for pH, Conductivity, & Temp
- Tanks level inputs: 2 x pH, 1 x Conductivity
- Inputs for Stand-by, and Flow
- 1 x 240Vac Alarm Relay O/P, 1 x RS485 O/P
- LCD displays show measured pH and Conductivity (mS)
- Manual/Automatic Temperature Compensation (for pH only)
- Max dosing alarms
- Compatible with most pH probes, and requires the EMEC Range of Conductivity Sensors
- Optional GSM/GPRS modem or Ethernet/LAN card for remote connectivity via webserver and alarming via SMS/e-mail
- Dual pH and Conductivity Measurement and Control
- Cooling Towers
- Agriculture
- Waste Water Treatment
- Water Tank Corrosion Control
- Dual Control of both pH and Turbidity Measurements
- 2 x ON/OFF (or PWM) & 2 x proportional pulse Outputs
- Dot matrix backlit LCD displays measured pH, NTU, temperature, date & time
- Programmable power-on delay
- High and low pH & NTU alarms, and max dosing alarms
- 3 x 4-20mA Outputs for pH, NTU & temperature
- Serial port for printer allows log printing
- RS485 for remote control
- Requires optional pH Sensor & EMEC Model ETORB2 Turbidity Probe
- Optional GSM/GPRS modem or Ethernet/LAN card for remote connectivity via webserver and alarming via SMS/e-mail
- Dual pH and Turbidity Measurement and Control
- Waste Water Treatment
- Pharmaceutical
- Dual Channel pH and Chlorine Control
- Probes Available for Free and Total Chlorine, and pH
- Programmable for dosing Acid and Chlorine
- Proportional or On/Off Control for pH and Chlorine
- Outputs: 1 x pH 240Vac Relay, 2 x pH Pulse, 1 x Cl2 240Vac Relay, 1 x Cl2 Pulse
- 3 x mA Outputs for pH, Chlorine & Temp
- Tanks level inputs: 2 x pH, 1 x Cl2
- Inputs for Stand-by, and Flow
- Alarm Relay Output and RS485 Port
- LCD display shows measured pH and Chlorine (mg/L)
- Manual/Automatic Temperature Compensation (for pH only)
- Max dosing alarms
- Compatible pH Probe required, and the EMEC Range of Chlorine Amperometric Sensors and Flow Cells
- Optional GSM/GPRS modem or Ethernet/LAN card for remote connectivity via webserver and alarming via SMS/e-mail
- pH Verification with Chlorine or Chlorine Dioxide Control
- Cooling Towers
- Nursery and Greenhouse
- Agriculture
- Waste Water Treatment
- Simultaneously displays 6 parameters and the status of each channel on the Wide, Back-lit LCD display screen
- Measurements available for pH, ORP, Chlorine (& Dioxide), Ozone, Turbidity, Dissolved Oxygen, Hydrogen Peroxide, Conductivity, Temperature, and mA Input
- User-friendly Touchscreen menu
- Plug and Play – Any combination of variables possible (pH, ORP, DO, CL2, TDS, mA)
- mA Inputs can be user-defined, customized, and scaled for example mA converted to Pressure
- Example of configuration: 3 x pH channels, 2 x ORP, 1 x Chlorine
- Inputs: 6 x mA or Sensor, 8 x Chemical Level, 2 x Water Meter, 1 x RS485 bus sensor
- Outputs: 6 x mA, 6 x On/off Relay, 8 x Proportional pulse, 2 x Free contact programmable Relay, 1 x Alarm Relay
- Relay (ON/OFF or PWM) or Pulse Proportional Control
- 2 x Water meter inputs to log flow rate and consumption
- Ethernet, and MODBUS RTU or TCP standard
- On-board Data Logging with USB port access
- Free Web-server Access for monitoring and control
- Optional Remote access via 4G or WiFi
- Optional Amperometric sensor & Inductive Conductivity Sensor cards are available
- IP65
- Multi Parameter Control of Water Variables from one location
- Cost Effective Remote and Local Monitoring and Control
- Space Saving Instrumentation
- Pharmaceutical
- Boiler and Cooling Towers
- Water and Waste Water
- Laboratory and R&D