Multi Parameter Water Analyzer / Controllers

For Ease of Use, Accuracy and Reliability, the EMEC and RealTech Controls range of Multi Parameter Water Analyzer / Controllers provide cost effective process monitoring and control. Dual and Multi-Variable Controllers are available for customized solutions.

For the complete range, and application assistance, please contact us.

The range of EMEC Multi Parameter Water Analyzer / Controllers are listed below:

Products

Model: ETX

Universal Dual Channel Controller

Model ETX Universal Multi Parameter Water Analyzer
  • Dual mA Outputs for the measured variables
  • 3 x Programmable relays for control or alarms
  • MODBUS RTU output
  • Simulation function for measured variables
  • Backlit LCD displays shows both measured variables, with % mA output
  • Auto-detects sensors for Chlorine, pH, ORP, Conductivity, Resistivity, and Dissolved Oxygen.
  • Optional HART output
  • Options for Loop Powered, or 24Vdc power supply
  • Manual/Automatic Temperature Compensation (for pH and Chlorine)
  • Water Sanitizer Control
  • Water / Waste Water Treatment
  • Greenhouse and Nursery
  • Swimming Pools and Fountains
  • Food and Beverage

Model: EMEC LDPHRH-MA

Dual Channel pH & ORP Controller

EMEC Model LDPHRH-MA Dual ORP & PH Multi Parameter Water Analyzer
Now available on e-store
  • Dual Control of both pH and ORP
  • BNC Connector Probe Connections
  • Programmable for dosing acid and/or base, and Chlorine
  • Proportional or On/Off Control for pH and ORP
  • Outputs: 1 x pH 240Vac Relay, 2 x pH Pulse, 1 x ORP 240Vac Relay, 1 x ORP Pulse
  • 3 x mA Outputs for pH, ORP & Temp
  • Tanks level inputs: 2 x pH, 1 x ORP
  • Inputs for Stand-by, and Flow
  • 1 x 240Vac Alarm Relay O/P, 1 x RS485 O/P
  • LCD displays show measured pH and ORP (mV)
  • Manual/Automatic Temperature Compensation (for pH only)
  • Max dosing alarms
  • Optional GSM/GPRS modem or Ethernet/LAN card for remote connectivity via webserver and alarming via SMS/e-mail
  • Water Sanitizer Control
  • Alternative to Chlorine or Chlorine Dioxide ppm Measurement
  • Greenhouse and Nursery
  • Waste Water Treatment

Model: EMEC LDPHPH-MA

Dual Channel pH Controller

EMEC Model LDPHPH-MA Dual Channel pH Multi Parameter Water Analyzer
Now available on e-store
  • Programmable for control of 2 individual pH systems
  • BNC Connectors for pH Probes
  • Proportional or On/Off Control 2 x pH systems
  • Control Outputs: 1 x pH1 240Vac Relay, 2 x pH1 Pulse, 1 x pH2 240Vac Relay, 1 x pH2 Pulse
  • 3 x mA Outputs for pH1, pH2 & Temp
  • Tanks Level inputs: 2 x pH1, 1 x pH2
  • Other I/O: 1 x Standby I/P, 1 x 240Vac Alarm Relay O/P, 1 x RS485 O/P
  • LCD displays shows both measured pH values
  • Manual/Automatic Temperature Compensation
  • Max dosing alarms
  • Optional GSM/GPRS modem or Ethernet/LAN card for remote connectivity via webserver and alarming via SMS/e-mail
  • Redundant pH Measurement and Control
  • Critical Process Monitoring and Control
  • Cost Effective – Dual Measurement on One Controller

Model: EMEC LDCDCD-MA

Dual Channel Conductivity Controller

EMEC Model LDCDCD-MA Dual Channel Conductivity Multi Parameter Water Analyzer
  • Dual Channel Conductivity Controller
  • Suits EMEC Conductivity Probes
  • Proportional or On/Off Control for 2 x Conductivity systems
  • Control Outputs: 1 x CD1 240Vac Relay, 2 x CD1 Pulse, 1 x CD2 240Vac Relay, 1 x CD2 Pulse
  • 3 x mA Outputs for CD1, CD2 & Temp
  • Tanks Level inputs: 2 x CD1, 1 x CD2
  • Other I/O: 1 x Standby I/P, 1 x 240Vac Alarm Relay O/P, 1 x RS485 O/P
  • LCD displays shows both measured Conductivity values
  • Manual/Automatic Temperature Compensation
  • Max dosing alarms
  • Optional GSM/GPRS modem or Ethernet/LAN card for remote connectivity via webserver and alarming via
  • Dual Conductivity Measurement and Control
  • Cooling Towers
  • Agriculture
  • Waste Water Treatment
  • Water Tank Corrosion Control

Model: EMEC LDPHCD-MA

Dual Channel pH & Conductivity Controller

Model: EMEC LDPHCD IND-MA

Dual Channel pH & Inductive Conductivity Controller

EMEC Model LDPHCD-MA pH & Conductivity Multi Parameter Water Analyzer
  • Dual Channel pH and Conductivity Controller
  • Programmable for dosing acid and/or base, and Conductivity control
  • Proportional or On/Off Control for pH and Conductivity
  • Outputs: 1 x pH 240Vac Relay, 2 x pH Pulse, 1 x Conductivity 240Vac Relay, 1 x Conductivity Pulse
  • 3 x mA Outputs for pH, Conductivity, & Temp
  • Tanks level inputs: 2 x pH, 1 x Conductivity
  • Inputs for Stand-by, and Flow
  • 1 x 240Vac Alarm Relay O/P, 1 x RS485 O/P
  • LCD displays show measured pH and Conductivity (mS)
  • Manual/Automatic Temperature Compensation (for pH only)
  • Max dosing alarms
  • Compatible with most pH probes, and requires the EMEC Range of Conductivity Sensors
  • Optional GSM/GPRS modem or Ethernet/LAN card for remote connectivity via webserver and alarming via SMS/e-mail
  • Dual pH and Conductivity Measurement and Control
  • Cooling Towers
  • Agriculture
  • Waste Water Treatment
  • Water Tank Corrosion Control

Model: EMEC LDPHTORB2-MA

Dual Channel pH & Turbidity Controller

Model: EMEC LDPHTORB2-IM-MA

Dual Channel pH & Turbidity Controller (for submersible probe)

EMEC Model LDPHTORBH-MA pH & Turbidity Multi Parameter Water Analyzer
  • Dual Control of both pH and Turbidity Measurements
  • 2 x ON/OFF (or PWM) & 2 x proportional pulse Outputs
  • Dot matrix backlit LCD displays measured pH, NTU, temperature, date & time
  • Programmable power-on delay
  • High and low pH & NTU alarms, and max dosing alarms
  • 3 x 4-20mA Outputs for pH, NTU & temperature
  • Serial port for printer allows log printing
  • RS485 for remote control
  • Requires optional pH Sensor & EMEC Model ETORB2 Turbidity Probe
  • Optional GSM/GPRS modem or Ethernet/LAN card for remote connectivity via webserver and alarming via SMS/e-mail
  • Dual pH and Turbidity Measurement and Control
  • Waste Water Treatment
  • Pharmaceutical

Model: EMEC LDPHCL1-MA

Dual Channel pH and Chlorine Controller (Closed Amperometric Cells)

Model: EMEC LDPHCL4-MA

Dual Channel pH and Chlorine Controller (Open Amperometric Cells)

EMEC Dual Channel pH and Chlorine Controller (Closed Amperometric Cells)
  • Dual Channel pH and Chlorine Control
  • Probes Available for Free and Total Chlorine, and pH
  • Programmable for dosing Acid and Chlorine
  • Proportional or On/Off Control for pH and Chlorine
  • Outputs: 1 x pH 240Vac Relay, 2 x pH Pulse, 1 x Cl2 240Vac Relay, 1 x Cl2 Pulse
  • 3 x mA Outputs for pH, Chlorine & Temp
  • Tanks level inputs: 2 x pH, 1 x Cl2
  • Inputs for Stand-by, and Flow
  • Alarm Relay Output and RS485 Port
  • LCD display shows measured pH and Chlorine (mg/L)
  • Manual/Automatic Temperature Compensation (for pH only)
  • Max dosing alarms
  • Compatible pH Probe required, and the EMEC Range of Chlorine Amperometric Sensors and Flow Cells
  • Optional GSM/GPRS modem or Ethernet/LAN card for remote connectivity via webserver and alarming via SMS/e-mail
  • pH Verification with Chlorine or Chlorine Dioxide Control
  • Cooling Towers
  • Nursery and Greenhouse
  • Agriculture
  • Waste Water Treatment

Model: EMEC CENTURIO PRO

Six Channel Controller

EMEC CENTURIO PRO 6 Channel Multi Parameter Water Analyzer
  • Simultaneously displays 6 parameters and the status of each channel on the Wide, Back-lit LCD display screen
  • Measurements available for pH, ORP, Chlorine (& Dioxide), Ozone, Turbidity, Dissolved Oxygen, Hydrogen Peroxide, Conductivity, Temperature, and mA Input
  • User-friendly Touchscreen menu
  • Plug and Play – Any combination of variables possible (pH, ORP, DO, CL2, TDS, mA)
  • mA Inputs can be user-defined, customized, and scaled for example mA converted to Pressure
  • Example of configuration: 3 x pH channels, 2 x ORP, 1 x Chlorine
  • Inputs: 6 x mA or Sensor, 8 x Chemical Level, 2 x Water Meter, 1 x RS485 bus sensor
  • Outputs: 6 x mA, 6 x On/off Relay, 8 x Proportional pulse, 2 x Free contact programmable Relay, 1 x Alarm Relay
  • Relay (ON/OFF or PWM) or Pulse Proportional Control
  • 2 x Water meter inputs to log flow rate and consumption
  • Ethernet, and MODBUS RTU or TCP standard
  • On-board Data Logging with USB port access
  • Free Web-server Access for monitoring and control
  • Optional Remote access via 4G or WiFi
  • Optional Amperometric sensor & Inductive Conductivity Sensor cards are available
  • IP65
  • Multi Parameter Control of Water Variables from one location
  • Cost Effective Remote and Local Monitoring and Control
  • Space Saving Instrumentation
  • Pharmaceutical
  • Boiler and Cooling Towers
  • Water and Waste Water
  • Laboratory and R&D

Related Products – Probes

Related Products – Probe Holders

Related Products – Dosing Pumps & Backboard Mounted Control Systems